AXON Light Baffle

The AXON Light Baffle is ideal for combining acoustics and lighting. The acoustically effective luminaire body, combined with the identical surface finish of the AXON Acoustic Baffle, creates a unified and homogeneous ceiling appearance.

In buildings with thermally activated ceilings, the AXON Light Baffle also serves as a design element that perfectly combines functionality and aesthetics. Furthermore, the products can be used in rooms where unobstructed access to and visibility of the ceiling must be ensured.

The AXON light baffle is a joint product development with RIDI Leuchten GmbH, with whom we collaborate as partners.

Ceiling
Wall
Room
Technology

Project Inspiration

Our AXON light baffles have already been used in numerous projects.
You can find a selection here:

Technical Specifications

Standard Color

white, similar to RAL 9003

Special Colors

by RAL or NCS code

Tension

≈ 220–240 V, 50–60 Hz

Protection Class

IP 20

Ballast Class

A1 BAT, EVG

Inrush Current / Inrush Time

35A / 193 µs

Power Factor

91%

Light Distribution

direct lighting or direct and indirect lighting

Light bulbs

LED Linear Modules

Color Temperature

830, 840

Color tolerance

initial < 3 SDCM

Glare Rating Index (UGR)

MPR <19, M1 >19, opal >19

Beam angle

65° (MPR, M1) – 120° (opal)

Energy Efficiency Class of LED Bulbs

A+

Energy Efficiency Class

A+

Service life

L80B50 50,000 h

Photobiological Safety According to EN 62471

RG1

Test Reports

for acoustic properties, cooling capacity curves, building material classes, mechanical strength

Phi_U

100%

Phi_o

0%

LITG/DIN

A50 (MPR, MPS) A40 (opal)

UTE

1.00D

Ambient temperature

min. 0°, max. +35°

Light output

directly

Symmetry

symmetrical

Diffuser

Satin-finished opal (transmission 72%), microprismatic with microlamellae, UGR < 19 (MPR)

CRI

≥ 80

Color Temperature (Kelvin)

3,000 K, 4,000 K

Assembly

Suspension Mount (Wire Rope)

Protection Class

I

Electrical Design

Electric converter for LEDs, switchable or dimmable, DALI

Electrical Connection

Continuous-light fixtures with the Wieland GST-Mini connector system; individual fixtures with power cord and terminal block

Light Distribution Curve

Photometric Representation of the Luminous Intensity Distribution

Lumens/Power (MPS model, 4000 K):

Note: Up to 15 elements, each 1,200 mm long, can be mounted in a linear configuration.
A Type B circuit breaker rated at 16 amps must be used.

Available dimensions:
Height: customizable
Width: 40 mm

Other sizes available upon request